196
Community Rules
You must post before you leave
Be nice. Assume others have good intent (within reason).
Block or ignore posts, comments, and users that irritate you in some way rather than engaging. Report if they are actually breaking community rules.
Use content warnings and/or mark as NSFW when appropriate. Most posts with content warnings likely need to be marked NSFW.
Most 196 posts are memes, shitposts, cute images, or even just recent things that happened, etc. There is no real theme, but try to avoid posts that are very inflammatory, offensive, very low quality, or very "off topic".
Bigotry is not allowed, this includes (but is not limited to): Homophobia, Transphobia, Racism, Sexism, Abelism, Classism, or discrimination based on things like Ethnicity, Nationality, Language, or Religion.
Avoid shilling for corporations, posting advertisements, or promoting exploitation of workers.
Proselytization, support, or defense of authoritarianism is not welcome. This includes but is not limited to: imperialism, nationalism, genocide denial, ethnic or racial supremacy, fascism, Nazism, Marxism-Leninism, Maoism, etc.
Avoid AI generated content.
Avoid misinformation.
Avoid incomprehensible posts.
No threats or personal attacks.
No spam.
Moderator Guidelines
Moderator Guidelines
- Don’t be mean to users. Be gentle or neutral.
- Most moderator actions which have a modlog message should include your username.
- When in doubt about whether or not a user is problematic, send them a DM.
- Don’t waste time debating/arguing with problematic users.
- Assume the best, but don’t tolerate sealioning/just asking questions/concern trolling.
- Ask another mod to take over cases you struggle with, if you get tired, or when things get personal.
- Ask the other mods for advice when things get complicated.
- Share everything you do in the mod matrix, both so several mods aren't unknowingly handling the same issues, but also so you can receive feedback on what you intend to do.
- Don't rush mod actions. If a case doesn't need to be handled right away, consider taking a short break before getting to it. This is to say, cool down and make room for feedback.
- Don’t perform too much moderation in the comments, except if you want a verdict to be public or to ask people to dial a convo down/stop. Single comment warnings are okay.
- Send users concise DMs about verdicts about them, such as bans etc, except in cases where it is clear we don’t want them at all, such as obvious transphobes. No need to notify someone they haven’t been banned of course.
- Explain to a user why their behavior is problematic and how it is distressing others rather than engage with whatever they are saying. Ask them to avoid this in the future and send them packing if they do not comply.
- First warn users, then temp ban them, then finally perma ban them when they break the rules or act inappropriately. Skip steps if necessary.
- Use neutral statements like “this statement can be considered transphobic” rather than “you are being transphobic”.
- No large decisions or actions without community input (polls or meta posts f.ex.).
- Large internal decisions (such as ousting a mod) might require a vote, needing more than 50% of the votes to pass. Also consider asking the community for feedback.
- Remember you are a voluntary moderator. You don’t get paid. Take a break when you need one. Perhaps ask another moderator to step in if necessary.
view the rest of the comments
Maintenance consultant who has not set foot on site writes a report recommending condition based maintenance including thermal imaging on all electrical equipment and didn't bother to see if it comes with an IR window... Hopefully this sticker convinces the boss to give up that plan.
I mean, all that thermal imaging is really doing is checking for hot spots. Just follow NFPA70B to find when you should be performing PMs on this transformer. But really the thermal imaging would tell you to tighten some bolts. Why not just clean the contacts and tighten the bolts? That's a shit consultant - recommending people try to kill them self to see if a bolt is loose is dumb. Turn the thing off and tighten the bolt.
An IR window won't tell you if the windings are going bad, and that's much more critical than the terminations. With the transformer de-energized, do a winding ratio test at the frequency recommended by NFPA70B, while you're tightening bolts.
The fucked up part is that maintenance consultant probably gets pedigree by commenting on the NFPA concensus review sessions to advocate for his way. Feel free to PM me if you need help getting that fucker walked off site. I love throwing the code book at people that try to kill maintenance workers.
It was a hypothetical situation, don't worry. Not really outside of the realm of things I've seen 🫠
I think it depends a lot on how critical the system is and what the risk of failure is. I work in critical infrastructure and we aren't going to rely on a code minimum PM schedule. We don't want to run our transformers to failure, even if we have redundancy, because lead times are fucking crazy right now. Like, more than a year. You are limited in terms of shelf spares due to space and storage/exercise requirements.
I'm not an electrical person but our electrical maintenance department seems to be on board with condition based maintenance so there must be some benefit to them. We do require IR windows and other features on equipment that allow the tests to be done safely. Apparently the IR windows are easy to retrofit.
The other benefit is tracking trends over time. Some of the offline analysis (like the winding ratio) you mentioned will give you data, but you can check more things and more frequently with the windows. You can see when a particular bus connection is slightly warmer than the others, for example, and decide to take it down sooner than required to have a look and correct.
It's a different situation than what we are describing but we recently had a motor failure and one of the three phases was getting slowly hotter over time (we had online trends) until it shorted and kablamo! No one was monitoring those temps but we sure are now lol.
That makes sense. I shouldn't have bashed IR windows. The plants that mandate rigid conduit everywhere, IR windows make sense and are good. For the limited budget plants, I think IR windows on transformers are low priority. But infinite budget, IR windows are great.
IR windows have a lot more use cases outside of transformers where I think they are more important. And everything has to do with frequency and down time availability.
The last job I worked was a steel mill. I was in charge of all electrical distribution from utility to disconnect prior to production equipment. Because of the metal dust, we needed to vacuum out distribution equipment yearly at a minimum and NFPA70B recommended some tasks yearly for us. I left when my 2 day outage on a 3 day weekend was canceled. I consolidated the outage plan to a single day, and they still wouldn't let me have it. Once we got a year behind, I left. I've been gone a year, and they still haven't done it.
I had the main transformers on a 5 year EOL plan because of oil samples and age. The lead time was 18 months for each, and they needed 3, lol. The EOL plan was also neglected.
I would've felt more comfy with IR windows lmao but I wasn't going to stick around to be the scape goat when the plant goes down.
I worked in chemical manufacturing before infrastructure and there is no way in hell I'm going back to anything that isn't strictly regulated lol.
Not that we don't get our fair share of nonsense, but manufacturing is a whole other world of crazy.