this post was submitted on 24 Jan 2026
201 points (96.7% liked)

Ask Lemmy

36998 readers
1308 users here now

A Fediverse community for open-ended, thought provoking questions


Rules: (interactive)


1) Be nice and; have funDoxxing, trolling, sealioning, racism, and toxicity are not welcomed in AskLemmy. Remember what your mother said: if you can't say something nice, don't say anything at all. In addition, the site-wide Lemmy.world terms of service also apply here. Please familiarize yourself with them


2) All posts must end with a '?'This is sort of like Jeopardy. Please phrase all post titles in the form of a proper question ending with ?


3) No spamPlease do not flood the community with nonsense. Actual suspected spammers will be banned on site. No astroturfing.


4) NSFW is okay, within reasonJust remember to tag posts with either a content warning or a [NSFW] tag. Overtly sexual posts are not allowed, please direct them to either !asklemmyafterdark@lemmy.world or !asklemmynsfw@lemmynsfw.com. NSFW comments should be restricted to posts tagged [NSFW].


5) This is not a support community.
It is not a place for 'how do I?', type questions. If you have any questions regarding the site itself or would like to report a community, please direct them to Lemmy.world Support or email info@lemmy.world. For other questions check our partnered communities list, or use the search function.


6) No US Politics.
Please don't post about current US Politics. If you need to do this, try !politicaldiscussion@lemmy.world or !askusa@discuss.online


Reminder: The terms of service apply here too.

Partnered Communities:

Tech Support

No Stupid Questions

You Should Know

Reddit

Jokes

Ask Ouija


Logo design credit goes to: tubbadu


founded 2 years ago
MODERATORS
 

It seems kind of primitive to have power lines just hanging on poles, right?

Bit unsightly too

Is it just a cost issue and is it actually significant when considering the cost of power loss on society (work, hospital, food, etc)?

you are viewing a single comment's thread
view the rest of the comments
[โ€“] axexrx@lemmy.world 8 points 3 days ago (1 children)

There are several environmental factors that generally contribute to underground viability.

Ground water- obviously flooding, but evem heavy rain areas, or just high humid soil levels can create problems (cables produce heat, while soil's usually cool so condensation can be a problem wherever theres a splice/ junction)

And speaking of cables producing heat, this can become its own problem. Dirt acts as an insulator for heat. Since the transfer of large amounts of electricity produces heat, unless your ground is cold enough to actively cool them, this means derating the cables (using much larger ones to transfer the same power) which greatly raises the cost.

This is why even in cooler climates, hi voltage / long range transfer is done above ground.

Earthquakes and ground frost difference issues can also cause cables to get sheared.

Ofc, above ground power has plenty of its own issues- trees falling forest fire areas, just general exposure to the elements.

But generally, ease and expense to fix issues, and relative lack of disruption to infrastructure while doing so, win out, Making above ground preferable if there are any potential issues with underground.

Theres also a bit of a political aspect that should be mentioned- who owns the lines- burial is always more costly, so if energy co's own the lines like in america, theyre rarely going to want to spend the extra money burrying and unburrying to fix/ add, unless its really more cost effective. (Or the municipality is footing the bill/ has already done the infrastructure, like a lot of denser urban areas in the US, like NYC and DC. )

[โ€“] palordrolap@fedia.io 1 points 2 days ago

Even in river valleys, the cabling tends to be well insulated and underground here. Again, unless it's especially rural.

I've seen places where basements / cellars have been completely submerged by freak floods and all the old electrical infrastructure (cables, meters, etc.) is still in place and back in use once everything has dried out, save perhaps for a few minor repairs.

But I get it. Where it's cheaper and the health and safety / OSHA / whatever it's called where you are, rules don't disallow it, overground is going to happen.