this post was submitted on 10 May 2025
801 points (99.8% liked)

pics

28269 readers
759 users here now

Rules:

1.. Please mark original photos with [OC] in the title if you're the photographer

2..Pictures containing a politician from any country or planet are prohibited, this is a community voted on rule.

3.. Image must be a photograph, no AI or digital art.

4.. No NSFW/Cosplay/Spam/Trolling images.

5.. Be civil. No racism or bigotry.

Photo of the Week Rule(s):

1.. On Fridays, the most upvoted original, marked [OC], photo posted between Friday and Thursday will be the next week's banner and featured photo.

2.. The weekly photos will be saved for an end of the year run off.

Weeks 2023

Instance-wide rules always apply. https://mastodon.world/about

founded 2 years ago
MODERATORS
 
all 50 comments
sorted by: hot top controversial new old
[–] TWeaK@lemm.ee 56 points 11 months ago (2 children)

Fun fact: You can estimate the voltage by the length of the insulators. My guess is this is around 100kV (2x 3 phase circuits), around the border of transmission and distribution voltages.

You can also estimate the capacity by the number of conductors per phase. This has a pair of lines for each phase, so a fair chunk, but not the 3 or 4 conductors you sometimes see (although maybe you mainly see that on higher transmission voltages.

[–] Jhestyr@lemmy.world 31 points 11 months ago (1 children)

Ooh a lightning sorcerer...

[–] InverseParallax@lemmy.world 17 points 11 months ago

There are some who call him: Tim?

[–] sartalon@lemmy.world 2 points 11 months ago* (last edited 11 months ago) (2 children)

It will be 128 kV or 345 kV.

[–] qupada@fedia.io 14 points 11 months ago (2 children)

OP appears to be in the UK, so potentially (no pun intended) one of 400kV, 275kV, or 132kV.

[–] TWeaK@lemm.ee 5 points 11 months ago* (last edited 11 months ago) (1 children)

That pun was totally intended, and I cannot fault you for it.

I was thinking 132kV, but wasn't sure if this is Europe where you might find 100kV (although again it varies by country). In the UK, 132kV is the boundary between distribution and transmission. DNO's (Distribution Network Operators) generally use 11kV, 33kV, 66kV (generally rare but used in some areas eg in North West England) and 132kV, TNO's (Transmission) use 132kV, 275kV and 400kV. Although, a lot of 275kV substations are built to 400kV spec (eg in Scotland), so that they can upgrade in the future.

You sometimes get this with power lines, they might install higher voltage insulators then run it at a lower voltage until some time later when the network is upgraded. This spoils the game of guess the voltage/makes it more challenging, and you end up with really weird looking connections between large pylons and small poles.

[–] CelloMike@lemmy.world 6 points 11 months ago

According to the national grid map this is a 275kv line so there you go :)

[–] ChickenLadyLovesLife@lemmy.world 2 points 11 months ago

no pun intended

None taken.

[–] TWeaK@lemm.ee 4 points 11 months ago

The more I look at it I think it might be a 132kV line on a 400kV tower, with the intention to upgrade it some time in the future. I say this because the insulators aren't actually the full length of the spacing from the tower, there's a separator between the tower and the start of the insulator fins. This makes me think they've left room for longer 400kV insulators to be installed.

Saying that though I have no idea, there could have been all sorts of other considerations that led to a configuration like that.

[–] ThePyroPython@lemmy.world 25 points 11 months ago (2 children)
[–] expatriado@lemmy.world 19 points 11 months ago* (last edited 11 months ago) (2 children)

i work for a utility company, we got even simpler ones on the wall 😄

[–] altima_neo@lemmy.zip 11 points 11 months ago (1 children)

That's some hot centerfolds

[–] ParadoxSeahorse@lemmy.world 3 points 11 months ago

The ThePyroPython Pylon

[–] Brunbrun6766@lemmy.world 20 points 11 months ago

Seems like something we should construct more of

[–] i_am_not_a_robot@feddit.uk 17 points 11 months ago (2 children)
[–] Genius@lemmy.zip 8 points 11 months ago (2 children)

Far over the misty pylons tall

[–] tetris11@feddit.uk 1 points 11 months ago* (last edited 11 months ago)

Two voltage deep, resistance Ohm

[–] Ste41th@lemmy.ml 16 points 11 months ago (1 children)

I like pictures like this, shows that the person who took it is somewhat creative and thinks out of the box.

[–] expatriado@lemmy.world 16 points 11 months ago (1 children)

thinks out of the box.

or inside the pylon

[–] Ste41th@lemmy.ml 2 points 11 months ago

Lmao yes indeed

[–] sneezycat@sopuli.xyz 14 points 11 months ago (1 children)

You are now trapped by my stand『SUPER FLY』

[–] ramius345@sh.itjust.works 12 points 11 months ago (1 children)
[–] PotatoLibre@feddit.it 12 points 11 months ago

I like when something usually considered just background becomes interesting.

[–] Appoxo@lemmy.dbzer0.com 12 points 11 months ago

I like geometric patterns :)

[–] Mustakrakish@lemmy.world 6 points 11 months ago (1 children)

If I remember correctly, you are now trapped there until you trick someone else into taking your spot.

[–] Couldbealeotard@lemmy.world 2 points 11 months ago

At least your knives will be sharp

[–] spittingimage@lemmy.world 6 points 11 months ago

Looking up an electricity pylon's skirt.

[–] huquad@lemmy.ml 5 points 11 months ago

Straight out of Dr. Strange

[–] Pnut@lemm.ee 5 points 11 months ago

The effing tower.

[–] xc2215x@lemmy.world 4 points 11 months ago

That looks super neat.

[–] daepicgamerbro69@lemmy.world 4 points 11 months ago (1 children)

Did you also get to see the Mona Lisa?

load more comments (1 replies)
[–] AngryCommieKender@lemmy.world 4 points 11 months ago

Did you get a buzzing sensation being under it?

[–] don@lemm.ee 4 points 11 months ago (1 children)

Looks like part of a space station orbiting a water planet

[–] stockhausen@sopuli.xyz 3 points 11 months ago

Damn, now I can't unsee it!

[–] Shardikprime@lemmy.world 3 points 11 months ago

Everyone who sees anything on this picture... Are you sure you are not enemy stand users?

[–] b_tr3e@feddit.org 3 points 11 months ago
  • escape route?
  • thermal starter?
  • timer?
  • thermite?
  • battery?

...good luck!

[–] Rebels_Droppin@lemmy.world 3 points 11 months ago

This, this I like.

[–] InfiniteHench@lemmy.world 3 points 11 months ago

Damn I’ve always wanted to stop along the highway and get a shot like this. Great pic. Thank you

[–] Doomsider@lemmy.world 2 points 11 months ago

Love this perspective shot.

damn the 5g radiation coming from this photo is enlarging my gayness allele

[–] markstos@lemmy.world 1 points 11 months ago

Some of these were installed on my family farm in the US through eminent domain. Meaning, we had no choice but the government was supposed to pay us a fair market value for the use of our land. I still remember that because that year all us three kids all got new bicycles!

I don't love them. If you are right underneath them, it seems like you feel the electricity and sometimes hear them crackle.