I'm having a rather strange problem with my Ender 3 V2 that's causing me to leave it unplugged and as a result underused.

I used to have my printer set up in my garage but one day noticed that the circuit breaker was tripping overnight resulting my refridgerator to turn off (not ideal.) I kept removing devices until I determined that it was caused by my 3d printer despite the PSU being completely flipped off at the back! This is obviously strange behavior and not ideal for a device that is outside of it's warranty period.

So I'm not sure how to proceed here. Firstly, what type of issue would cause this device to trigger a circuit breaker even when the PSU is turned off? Secondly, is there some way to fix this device that isn't a major PITA? Has anyone else experienced this as well?

you are viewing a single comment's thread
view the rest of the comments
[–] cmnybo@discuss.tchncs.de 4 points 5 days ago (7 children)

Is it plugged into a GFCI protected outlet?

The power supply will have RFI filters in it and they always have some leakage. They may be installed before the power switch. There could just be too many devices with some earth leakage connected to the circuit, causing it to trip without any of them being faulty.

[–] roofuskit@lemmy.world 2 points 4 days ago (2 children)

If the outlet is GFCI it would trip instead of the breaker.

[–] cmnybo@discuss.tchncs.de 1 points 4 days ago (1 children)

It's pretty common to have breakers with built in GFCI these days.

[–] roofuskit@lemmy.world 3 points 4 days ago* (last edited 4 days ago)

It's pretty common to assume that when someone uses the word outlet that they meant outlet.

Is it plugged into a GFCI protected outlet?

load more comments (4 replies)