this post was submitted on 01 Aug 2026
254 points (98.8% liked)

Technology

86864 readers
2925 users here now

This is a most excellent place for technology news and articles.


Our Rules


  1. Follow the lemmy.world rules.
  2. Only tech related news or articles.
  3. Be excellent to each other!
  4. Mod approved content bots can post up to 10 articles per day.
  5. Threads asking for personal tech support may be deleted.
  6. Politics threads may be removed.
  7. No memes allowed as posts, OK to post as comments.
  8. Only approved bots from the list below, this includes using AI responses and summaries. To ask if your bot can be added please contact a mod.
  9. Check for duplicates before posting, duplicates may be removed
  10. Accounts 7 days and younger will have their posts automatically removed.

Approved Bots


founded 3 years ago
MODERATORS
 
you are viewing a single comment's thread
view the rest of the comments
[–] Senal@programming.dev 1 points 2 days ago (1 children)

Not strictly, there are usualy hurdles to overcome for home usage of datacentre tech, but it's possible.

An easy example that comes to mind is that the datacentre GPU's might have cooling configurations that rely on a large amount of airflow from the surrounding cabinet, which you'll get in a datacentre, but not so much in a personal tower.

Also, noise, in a datacentre, noise is much less of an issue than in a personal computer, so they can eschew noise reduction in favour of performance.

Many people that live near data-centres would disagree, but i mean strictly from a usage point of view, not a broader community perspective.

[–] GamingChairModel@lemmy.world 2 points 1 day ago (1 children)

Not strictly, there are usualy hurdles to overcome for home usage of datacentre tech, but it's possible.

The hurdles are basically insurmountable with the hardware released after 2024.

The NVL72 for the Blackwell generation cost about $3 million and takes up a single server rack. The power consumption is about 130 kW, and most configurations require dedicated plumbing for the liquid cooling.

To put things in perspective, a residential electrical hookup is usually 50A or 100A for a house, with recommendations that anyone who is going to be charging electric cars should have 100A service. 100A at 240V is 24 kW.

So one server rack uses as much power as the maximum electrical capacity of 5 homes. You'll never be able to pull that off in an actual residential environment.

Oh, and the newest 2026 generation, the Rubin NVL72s, use something like 230 kW of electrical power, almost twice as much as the previous 2024 generation.

[–] Senal@programming.dev 1 points 1 day ago

i was talking more of the prosumer and close to prosumer units that could theoretically be retrofitted or housed in homelabs.

If datacentres went down en-masse i'd assume there'd be mix of hardware generations there.

Damn though, i didn't know anything about the stuff you just mentioned, so my estimates of what could be available/usable are probably way off.

Now i have to go and do a deep dive, thanks.