23
GPR testing on an above grade slab
(lemmy.ca)
Geophysics community, not restricted to Canada.
General rules: must be geophysics related or adjacent (this is a very wide scope, and includes things like stellar earthquakes); must adhere to lemmy.ca moderation rules; no pseudoscience.
See also !geology@lemmy.ca
Wavey line is rebar -- the radar reflections take the shape of hyperbola as you pass over them. Bottom of the concrete is just below the rebar (those hyperbola overprint it a bit, so it's harder to see). Then it's crushed rock fill (probably limestone) until the two metre mark.
Very cool, thanks for the explanation. What's the purpose of the inspection? Is it to verify the correct slab and/or subgrade thickness? Or the presence of rebar?
In my particular case, the purpose was testing the equipment over a target that I can use to confirm it is working as expected.
But GPR in concrete can be used for all the purposes you mention. It can also be used to find voids, verify "as-built" drawings, etc. Some of our clients use it simply to avoid drilling into rebar when installing anchor bolts for shelving or whatever.
My background isn't concrete, so I don't do the more advanced things with it :)