Mildly Infuriating
Home to all things "Mildly Infuriating" Not infuriating, not enraging. Mildly Infuriating. All posts should reflect that. Please post actually infuriating posts to !actually_infuriating@lemmy.world
I want my day mildly ruined, not completely ruined. Please remember to refrain from reposting old content. If you post a post from reddit it is good practice to include a link and credit the OP. I'm not about stealing content!
It's just good to get something in this website for casual viewing whilst refreshing original content is added overtime.
Rules:
1. Be Respectful
Refrain from using harmful language pertaining to a protected characteristic: e.g. race, gender, sexuality, disability or religion.
Refrain from being argumentative when responding or commenting to posts/replies. Personal attacks are not welcome here.
...
2. No Illegal Content
Content that violates the law. Any post/comment found to be in breach of common law will be removed and given to the authorities if required.
That means: -No promoting violence/threats against any individuals
-No CSA content or Revenge Porn
-No sharing private/personal information (Doxxing)
...
3. No Spam
Posting the same post, no matter the intent is against the rules.
-If you have posted content, please refrain from re-posting said content within this community.
-Do not spam posts with intent to harass, annoy, bully, advertise, scam or harm this community.
-No posting Scams/Advertisements/Phishing Links/IP Grabbers
-No Bots, Bots will be banned from the community.
...
4. No Porn/Explicit
Content
-Do not post explicit content. Lemmy.World is not the instance for NSFW content.
-Do not post Gore or Shock Content.
...
5. No Enciting Harassment,
Brigading, Doxxing or Witch Hunts
-Do not Brigade other Communities
-No calls to action against other communities/users within Lemmy or outside of Lemmy.
-No Witch Hunts against users/communities.
-No content that harasses members within or outside of the community.
...
6. NSFW should be behind NSFW tags.
-Content that is NSFW should be behind NSFW tags.
-Content that might be distressing should be kept behind NSFW tags.
...
7. Content should match the theme of this community.
-Content should be Mildly infuriating. If your post better fits !Actually_Infuriating put it there.
-The Community !actuallyinfuriating has been born so that's where you should post the big stuff.
...
8. Reposting of Reddit content is permitted, try to credit the OC.
-Please consider crediting the OC when reposting content. A name of the user or a link to the original post is sufficient.
...
...
Also check out:
Partnered Communities:
Reach out to LillianVS for inclusion on the sidebar.
All communities included on the sidebar are to be made in compliance with the instance rules.
view the rest of the comments
ANY cable being driven above it's rated load is a fire hazard. There healthy margins in those ratings, so going slightly over is likely not going to have any affect, but those margins are for good reason (namely people like you thinking it's fine to plug a 15A cable into a 20A circuit without external fusing or current limiting), and deliberately overloading any part of an electric circuit is ALWAYS dangerous and stupid. And what about 7A cables you can get in japan ? you can explicitly get 0.75mm² cables, which are only rated to 7Amps. Just as confident of blasting 20A through those ? Almost 9 times the amount of waste heat being generated in the core than at it's max rated load.
Nope, again completely untrue. Breakers are only required to trip if the circuit becomes overloaded.
Your breakers don't, and can't give a shit about what's happening on the other side of the outlet.
Your device could slowly be melting itself into a pile of burning plastic, as long as it's drawing less than 16 Amps to do so, the breakers will not trip. As I've pointed out, repeatedly already, and you have repeatedly ignored, breakers are solely and exclusively for protecting the wire from overheating /overloading.
And in fact, the fused plugs actually make it way MORE likely for something to trip on a device side fault in the UK, because the current only has to be like 3Amps to kill the fuse. In every other place of the world, current needs to be at least 16A before anything trips.
I address that point, quite literally, in a later a paraph where I write
So what happened here ? Did you not read my comment ? Did you not understand it ? Or did you read it understand, and then continue to pretend like I haven't already explicitly addressed this anyway ?
At this point I think calling this behaviour accidental would be an insult to your intelligence, and just have assume that you know exactly what you're doing, and are knowingly and deliberately arguing in bad faith and with intellectually dishonesty, so stop. Just go away. I'm done. You're either fully incapable of, or unwilling too, engage in honest debate, so I'm not linger interested in continuing this.
Breakers are only required to trip if the circuit is overloaded. That part is correct.
The internal resistance of drastically undersized wiring may not be capable of passing sufficient current to overload the household breaker. And yet, pretty much the entire world (except the UK) doesn't require fuses on their plugs. The unfused power cords for those non-UK appliances are either a fire hazard OR those cords are required to be able to carry sufficient current to trip the current limiter without catching fire. The latter is, indeed, the case. This is a big part of UL, CSA, CE, and other electrical certification standards around the world.
That's actually part of NEC code applicable in the US and Canada, and I'm not going to delve too far into it, as it really pisses me off. Basically, there is no functional difference between our 15A and 20A components. The standards needed for a component to carry 15A in North America are the same as the standards needed for it to carry 20A. Effectively, our 15A components have a safety margin 5A greater than that of our 20A components.
The historic and technical distinctions for this are well outside the scope of this discussion, and I think it is, indeed, moronic. But yes, technically, we can indeed use certain 15A-rated components on a circuit protected by a 20A breaker.
Here again, you're demonstrating my exact point, despite claiming that what I am saying is "completely untrue": The rest of the world builds its appliances to tolerate at least that 16A fault. For the UK to use that exact same manner of protection, they would need to build their appliances to tolerate a 30A fault. The same appliance would need a much heavier power cord in the UK than in the EU.
Since no rational person would want to overbuild each and every appliance to be able to tolerate a 30A fault, they included a fuse in their plug. That plug, unneeded in the rest of the world, is an essential component in the UK. That plug is what allows the UK to be able to safely use the world's 16A appliances on UK 30A breakers.
(No, the rest of the world doesn't need 16A before "anything" trips. The rest of the world includes their fuses inside the appliance, immediately after the cord rather than on the plug end.)
Yeah. If you undersized a en entire houses ring circuit at AWG24, then indeed a 30A fuse wouldn't be tripped. Though on the plus side, to even achieve it you would need to undersize the wire to such a massive degree that the wire itself just becomes a fuse.
In a our real world overhere, of fucking course a ring circuit can pass enough current to trip it's breaker, and it's fucking laughable to claim they can't.
No they don't. They can actually use much smaller power cords. Because there's a fuse in the plug itself. If the plug itself has 1A fuse, then no matter what happens, the maximum amount of current the device can ever consume is 1A, so 1A is the highest fault current that device will ever have to handle. The UK system actually makes fault protection on the device side much better and easiest.
Appliance wiring, not household wiring. I clearly specified that. You're reading what you want to read, and not what I actually wrote. You're laughing at yourself, not at what I claimed.
Remember: most of the world safely uses unfused plugs on their appliance power cords. Their 16A household breaker is the only current limiter available to protect those unfused power cables. Those normal sized, unfused cables would be drastically undersized if plugged into a less-restrictive, 30A outlet.